Framing Camera Fliter Response Parameters: Add files to represent the framing camera's response by clicking on
the Add... button to add FFC_Filter_1.
Highlight FFC_Filter_1 in the table and make sure that Filter Name also says FFC_Filter_1.
Filter Properties: Filter Type: select the FileFile" radio button, browse to the Examples -> Radjet folder and select FFC_01.frf.
Next click Add again in the Framing Camera Filter Response Parameters and highlight the newly added FFC_Filter_2 in the table so that it appears in the Filter Name.
Now set the Filter Type for FFC_Filter_2 by selecting the File radio button; browse and searching for FFC_02.frf in the Examples -> Radjet directory.