CONTENTS
GLOSSARY
SUBJECT INDEX
SEARCH DOCUMENTATION
Sample Problem: Z-Pinch Hohlraum
Setting Up the Grid: Slotted Return Current Can
To set up a return current can with 9 open slots:
Select
Target | Add Object
.
Select "Slotted Hohlraum" for the target component type.
Set the object name to "Hohlraum".
In the
Position
tab of the Object Parameters Dialog:
For the Reference Coordinate System, use "Target Chamber".
Use the default object position:
r
= (0,0,0).
Use the default orientation angles (all angles zero).
In the
Size/Gridding
tab of the Object Parameters Dialog:
Set the radius to 2.5cm.
Set the length to 2.0 cm.
Set the slot height to 1.8cm.
Set the slot width to 1.0 cm.
For the grid points, use 10 along the Z-axis, 9 slots, 3 azimuthal points per wall, 2 azimuthal points per slot.
Select "OK". (The return current can wall is added to the graph frame.)